    271 - Self-contained split unit axial fan low profile set - Heat pump

    271CONDXB
    SELECCIONAR PRODUCTO
    Formed by DXCBZ outdoor unit and FTBZ indoor unit model 271.

    271 - Outdoor unit DXCBZ - Heat pump

    Description
    The equipment described in this document are outdoor units for air to air heat pumps (DXCBZ series).
    These units are designed to operate together with any indoor unit of our manufacture of equivalent capacity, although the basic set is with indoor units from FTBZ series.

    Cabinet
    Made of high quality galvanized steel plate, finished with electrostatically applied and oven polymerized polyester powder for optimal resistance in outdoor conditions.
    Compressor and side containing refrigerant parts is lined with thermo-acoustic insulation.

    Refrigerant Circuit
    Made of refrigeration grade copper tubing, cleansed and dehydrated, incorporates Schrader Valves for easy access, vacuum, refrigerant charging and maintenance. Expansion made by means of a restrictor. Suction accumulator to protect compressor against liquid refrigerant and to facilitate oil recovery. Reversing valve Solenoid operated Schräder valves.
    Brazing is made with silver alloy soldering. Units are supplied with flare valves and R407c charge (5m).

    Compressors
    Compressor is rotary or Scroll type depending upon model, with inherent thermal protection and the corresponding oil charge. Compressor is mounted on the base (chassis) by means of vibration absorbers and is acoustically insulated. All this guarantees a silent, vibration free operation. Compressor also incorporates crankcase heater.

    Heat Exchangers
    Made of coated (blue) aluminium fins and copper tubing 3/8", mechanically expanded and of high heat exchange efficiency.

    Fans
    Propeller type, direct drive with single phase motor, 6 & 8 pole depending on models. One fan up to model 351, two fans for the rest of models (371 up to 501). Fans have low noise levels and incorporate pre-lubricated bearings that are statically and dynamically balanced.

    Control System (DXCBZ with FTBZ)
    Contactor for compressor and fan motors. The basic standard control system for the units is a wired, wall-mounted controller (or infrared) featuring all the necessary functions including programming for a week. The electronic board is incorporated in the indoor unit and allows for high/low pressure controls, compressor time delay, frost-protection in indoor unit, defrost system, on-off outdoor fan for low ambient operation, etc.

    Options
    – Head pressure control (fan speed control) for operation at low ambient temperatures (below 18ºC).
    – Controller system by conventional room thermostat, one stage cooling / one stage heating.
    – Infrared remote controller (with up to three sensors).

    Electric Supply
    Mod. 171, 201, 221, 251, 271 230.I, 50 Hz~.
    Mod. 351 230.I ó 400.III+N, 50 Hz~.
    Mod. 371, 401, 501, 701, 721 400.III+N, 50 Hz~.
    Other voltages and frequencies upon request.

    271 - Ìndoor unit FTBZ - Heat pump

    General
    Series FTBZ are ductable DX indoor units, cooling only or heat pump. Shallow design suitable for ceiling void location. Units have been developed to operate together with the DXCZ, DXCBZ series outdoor units but may be matched to other outdoor units of our manufacture of equivalent capacity. Units may be used to operate with free air discharge by means of a discharge plenum.

    Casing
    Made of high quality galvanized steel plate, the assembly is insulated with thermo-acoustic material.

    Refrigerant Circuit
    Is made of refrigeration grade copper tubing, thoroughly cleaned and dehydrated. Brazing is made with silver alloy soldering. These units are supplied hermetically sealed and include a Nitrogen charge.

    Indoor Heat Exchanger
    Made of copper tubing 3/8", mechanically expanded and aluminium fins.

    Fans
    Two centrifugal fans, double inlet, direct driven by means of a three-speed single phase motor (230.1.50Hz) with capacitor. Fans are of reduced sound level, they incorporate prelubricated bearings and are statically and dynamically balanced.

    Expansion device
    Is a "restrictor" (calibrated orifice).

    Air filter
    Polyurethane foam, auto-extinguishable and washable. Fire classification M1.

    Options:
    – Electric heaters
    – L.P. Hot water heating coils
    – Discharge plenum
    – Tubular discharge plenum
    – Air return plenum
    – High efficiency air filter
    – Mixing damper
    – Condensate pump
    – Remote control system (infrared)
    – Room thermostat

    Power supply
    All models 230V.1Ph.50Hz
    ×
    Filtros
    Visualizar en modo Cuadrícula Visualizar en modo Listado
    anterior
    página de
    siguiente
    Las cookies nos permiten ofrecer nuestros servicios de forma más rápida y personalizada. Al acceder y continuar navegando en esta web acepta el uso de cookies. Para más información, lea nuestra Política de cookies
    Aceptar
    X

    Suscríbete!

    56.000 usuarios

    ya reciben toda la actualidad de la
    Arquitectura, Ingeniería y Construcción

    SUSCRÍBETE